Model GNT - S.S. NPT Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GNP - S.S. NPT Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GNT HT - S.S. NPT Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GFT - S.S. RF ANSI Flange Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GFP - S.S. RF ANSI Flange Fitting for Chemical
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GFT HT - S.S. RF ANSI Flange Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GTT - S.S. Flared Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GTP - S.S. Flared Fitting
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GSCPS - S.S. Sanitary Clamp
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
This meter meets the strict 3-A Sanitary Standards using the new “Third Party Verification (TPV) program. Our methods of design, construction and traceability of components have been reviewed and approved.
The internals of this meter are machined or polished to meet 3-A self-draining and cleaning requirements. The GSCPS Meter meets Clean in Place (CIP), Steam in Place
Catalog
Manual
|
 |
 |
 |
 |
 |
 |
Model GSCP - S.S. Sanitary Clamp
Accuracy: ± 0.5% of the true flow at any point within the linear range of the turbine.
Repeatability: ± 0.1% of the indicated flow throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Linearity: ± 0.5% of the mean K-Factor throughout the linear range.
(Based on ISA SPEC, ANSI/ISA-RP31.1, ISA-S37.1)
Use this meter in pre-process applications where high accuracy is required without 3-A Approval.
Catalog
Manual
|